PROBLEM
The transceiver does
• Bad connection to the power supply.
not turn ON.
Little or no sound comes
• Squelch level is set too high.
from the speaker.
• Volume level is set too low.
• Speaker has been exposed to water.
Transmitting is impossi-
• Some channels are programmed for low
ble, or high power can-
power or receive only by regulations.
not be selected.
• The output power is set to low.
Scan does not start.
• More than 2 favorite channels are not pro-
grammed.
No beep sounds.
• Beep tones are turned OFF.
Distress calls cannot be
• MMSI (DSC self ID) code is not pro-
transmitted.
grammed.
Does not record or does
• The memory IC is not working.
not record properly.
POSSIBLE CAUSE

TROUBLESHOOTING

SOLUTION
• Check the connection to the transceiver and
power supply.
• Set the squelch to the threshold point.
• Set the volume to a suitable level.
• Remove the water with the AquaQuake func-
tion.
• Change channels.
• Push [HI/LO] to select high power.
• Set the desired channels as Favorite chan-
nels.
• Turn the beep tones ON in the CONFIGURA-
TION menu.
• Program the MMSI (DSC self ID) code.
• The memory IC should be replaced.
Ask your service center or technical dealer
for details.
16
1
REF.
p. 95
2
3
p. 3
4
p. 3
p. 14
5
6
pp. 9,
10
7
p. 11
8
p. 16
9
p. 86
10
11
p. 7
12
13
14
15
16
111

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC-M506GE and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ic-m506

Table of Contents