Appendix A - Specifi Cations And Optional Equipment; Inverter/Charger Specifi Cations - Magnum Energy MagnaSine Hybrid Owner's Manual

Renewable energy pure sine wave inverter/charger
Table of Contents

Advertisement

Appendix A – Specifi cations
Appendix A – Specifi cations and Optional Equipment
A-1 Inverter/Charger Specifi cations
Inverter Specifi cations
Input battery voltage range
Absolute maximum DC input
AC output voltage accuracy
Output frequency and accuracy
Total Harmonic Distortion (THD)
Continuous power output (at 25°C)
Continuous AC output current
1 msec surge current (amps AC)
100 msec surge current (amps AC)
5 sec surge power (real watts)
30 sec surge power (real watts)
5 min surge power (real watts)
30 min surge power (real watts)
Maximum continuous input current
Inverter effi ciency (peak)
HBCO/HBCI (High Battery Cut Out/In)
LBCO/LBCI (Low Battery Cut Out/In)
Inverter stacking (series or parallel)
AC relay transfer time (minimum)
Power consumption – searching
Power consumption – inverting (no load)
Output waveform
Charger Specifi cations
Continuous charger output at 25°C
Input current for continuous rated output
Maximum current during load support
Charger effi ciency
AC input frequency range
AC input voltage range
Power factor
General Features and Capabilities
Transfer relay capability
Five-stage charging capability
Battery temperature compensation
Internal cooling
Overcurrent protection
Over-temperature protection
Corrosion protection
Safety listings
Warranty
Branch-rated output circuit breakers
Environmental Specifi cations
Operating temperature
Non-operating temperature
Operating humidity
Physical Specifi cations
Unit dimensions (length x width x height)
Shipping dimensions (l x w x h)
Mounting
Weight
Max operating altitude
Specifi cations @ 25°C – Subject to change without notice.
Page 44
Model
Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Standard with available temp sensor connected (battery temp 0-50 °C)
0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan
PCB's conformal coated, powder coated chassis/top, and stainless steel fasteners
Shelf or wall (vents not allowed to face downward unless ME-CB or MMP is installed)
MSH4024RE
18.0 to 34.0 VDC
35 VDC
120 VAC ±3% (≤ continuous power)
60 Hz ± 0.05 Hz
< 5%
4000 VA
33 A
120
72
5800
5400
4900
4500
267 ADC
93.7%
33.6 VDC/33.0 VDC
18.0 VDC (adj)/25.0 VDC
No
<16 msec
<7 watts
25 watts
Pure Sine Wave
110 ADC
29 AAC
160 ADC
85%
50 to 70 Hz
60 to 140 VAC (120 VAC nominal)
> 0.95
60 AAC maximum each input
with two overlapping circuits
on transformer, MOSFETS, and battery
ETL listed to UL/cUL 1741, CSA C22.2 No. 107.1-01
3 years parts and labor
No
-20°C to +60°C (-4°F to 140°F)
-40°C to +70°C (-40°F to 158°F)
0 to 95% RH non-condensing
13.75" x 12.65" x 8.0" (34.9 cm x 32.1 cm x 20.3 cm)
19.0" x 17.0" x 13.0" (48.3 cm x 43.2 cm x 33.0 cm)
Unit: 58 lb (26.3 kg) / Shipping: 60 lb (27.2 kg)
15,000 ft (4570 m)
© 2013 Magnum Energy, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msh4024re