Appendix A - Specifi Cations And Optional Equipment; Table A-1, Ms-Pae Specifications (At 25°C) - Magnum Energy Sensata MagnaSine Owner's Manual

Pure sine wave inverter/charger
Table of Contents

Advertisement

Appendix A – Specifi cations and Optional Equipment
Models
Inverter Specifi cations
Input battery voltage range
Absolute maximum DC input
Nominal AC output voltage
AC output voltage accuracy
Output frequency and accuracy
Total Harmonic Distortion (THD)
Continuous power output at 25°C
Continuous AC output current
1 msec surge current (AAC)
100 msec surge current (AAC)
5 sec surge power (real watts)
30 sec surge power (real watts)
5 min surge power (real watts)
30 min surge power (real watts)
Max. continuous input current
Inverter effi ciency (peak)
Transfer time
Search mode (typical)
No load (120 VAC output, typical)
Waveform
Charger Specifi cations
AC input range
Continuous output at 25°C
Charger effi ciency
Power factor
Input current at rated output
General Features and Capabilities
Transfer relay capability
Five-stage charging capability
Battery temp compensation
Internal cooling
Overcurrent protection
Over-temperature protection
Corrosive protection
Listings
Warranty (Parts & Labor)
Environmental Specifi cations
Operating temperature
Non-operating temperature
Operating humidity
Physical Specifi cations
Unit Dimensions (L x W x H)
Shipping dimensions (L x W x H)
Mounting
Unit/Shipping weight
© 2017 Sensata Technologies
Appendix A – Specifi cations and Optional Equipment
Table A-1, MS-PAE Specifi cations (
MS4024PAE
18.0 to 34.0 VDC
L-N: 120 VAC ±5%, L-L: 240 VAC ±5% (≤ continuous power)
4000 VA (L-L)
L-N: 27.0 A/120 VAC, L-L: 16.7 A/240 VAC
L-N: 72, L-L 40
27 watts
105 ADC
15 AAC/leg at 120/240 VAC split phase
Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
0 to 120 cfm variable speed drive using dual 92 mm brushless DC fans
PCBs conformal coated, powder-coated chassis & top, stainless steel fasteners
ETL Listed to ANSI/UL1741, 1st edition, and CSA STD C22.2 No. 107.1-01
3 yrs parts and labor (extends to 5 yrs when purchased with and installed on MP/MMP system)
55 lb (24.9 kg) / 62 lb (28.2 kg)
50 VDC
120/240 VAC split phase
60 Hz ± 0.1 Hz
< 5%
L-N: 29.7 A/120 VAC, L-L: 18.3 A/240 VAC
L-N: 120, L-L 70
5800
5200
4800
4500
266A
93%
16 mSecs
< 6 watts
Pure Sine Wave
60 to 140 VAC / 50 to 70 Hz
85%
> 0.95
17.5 AAC/leg at 120/240 VAC split phase
2 legs at 30A per leg transfer standard
Yes, 15 ft Battery temp sensor standard
Yes, with two overlapping circuits
Yes on transformers, MOSFETS, and battery
–20°C to +60°C (-4°F to 140°F)
–40°C to +70°C (-40°F to 158°F)
0 to 95% RH non-condensing
13.75" x 12.65" x 8.0" (34.9 cm x 32.1 cm x 20.3 cm)
18.5" x 17.5" x 12.5" (47 cm x 44.5 cm x 31.8 cm)
Shelf, wall (no vents on bottom), MP or MMP panels
)
at 25°C
MS4448PAE
36.0 to 64.0 VDC
68 VDC
4400 VA (L-L)
L-N: 75, L-L 40
8500
6000
5400
4800
144A
94%
25 watts
60 ADC
55 lb (24.9 kg) / 63 lb (29.6 kg)
Page 49