Appendix A - Specifi Cations And Optional Equipment; Inverter/Charger Specifi Cations - Magnum Energy MS Series Owner's Manual

Ms series pure sine wave inverter/charger
Hide thumbs Also See for MS Series:
Table of Contents

Advertisement

Appendix A - Specifi cations and Optional Equipment
A-1 Inverter/Charger Specifi cations
Inverter Specifi cations
Input battery voltage range
Absolute maximum DC input
AC output voltage accuracy
Output frequency and accuracy
Total Harmonic Distortion (THD)
Continuous power output (at 25° C)
Continuous AC output current
1 msec surge current (amps AC)
100 msec surge current (amps AC)
5 sec surge power (real watts)
30 sec surge power (real watts)
5 min surge power (real watts)
30 min surge power (real watts)
Maximum continuous input current
Inverter effi ciency (peak)
HBCO/HBCI (High Battery Cut Out/In)
LBCO/LBCI (Low Battery Cut Out/In)
Series Stacking for 120/240 VAC
AC Relay Transfer time (minimum)
Power Consumption - searching
Power Consumption - inverting (no load)
Output Waveform
Charger Specifi cations
Continuous charger output at 25°C
Input current for continuous rated output
Charger effi ciency
AC input frequency range
AC input voltage range
Power factor
General Features and Capabilities
Transfer relay capability
Five-stage charging capability
Battery temperature compensation
Internal Cooling
Overcurrent protection
Overtemperature Protection
Corrosion protection
Safety Listings
Warranty
Branch rated output circuit breakers
Environmental Specifi cations
Operating temperature
Non-Operating temperature
Operating humidity
Physical Specifi cations
Unit Dimensions (h x w x d)
Shipping Dimensions (h x w x d)
Mounting
Unit Weight
Shipping Weight
Max operating altitude
* pass-thru on -15B and -20B models limited by output breakers
Specifi cations @ 25°C - Subject to change without notice.
© 2009 Magnum Energy Inc.
MS2012 (-15B, -20B)
9.0 to 16.8 VDC
25 VDC
120 VAC ±5% (≤ continuous power)
2000 VA
17 A
50
33
3300
3100
2800
2200
222 ADC
90.6%
16.8 VDC/16.5 VDC
9.0 VDC (adj)/12.5 VDC
No
25 watts
100 ADC
15 AAC
60 to 140 VAC (120 VAC nominal)
30 AAC maximum each input (60 AAC total)*
Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Standard with available temp sensor connected (battery temp 0 - 50 °C)
0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan
on transformer, MOSFETS, and temperature
PCB's conformal coated, powder coated chassis/top, and stainless steel fasteners
ETL listed to UL/cUL STD 458, UL STD 1741 and CSA STD C22.2 No. 107.1-01
only on MS2012 -15B (15A x2) and MS2012-20B (20A x2) models.
-20°C to +60°C (-4°F to 140°F)
-40°C to +70°C (-40°F to 158°F)
13.75" x 12.65" x 8.0" (34.9 cm x 32.1 cm x 20.3 cm)
18.5" x 17.5" x 12.5" (47 cm x 44.5 cm x 31.8 cm)
Shelf or wall (vents not allowed to face downward unless ME-CB is installed)
43 lb (19.5 kg)
46 lb (20.9 kg)
Appendix A - Specifi cations
MS2812
9.0 to 16.8 VDC
25 VDC
60 Hz ± 0.1 Hz
< 5%
2800 VA
23 A
70
40
3900
3800
3200
3000
311 ADC
90%
16.8 VDC/16.5 VDC
9.0 VDC (adj)/12.5 VDC
No
16 msec
<8 watts
30 watts
Pure Sine Wave
125 ADC
18 AAC
85%
50 to 70 Hz
> 0.95
with two overlapping circuits
3 years parts and labor
0 to 95% RH non-condensing
53 lb (24.0 kg)
56 lb (25.4 kg)
15,000' (4570 m)
MS4024
18.0 to 33.6 VDC
35 VDC
4000 VA
33 A
120
82
5800
5400
4900
4500
222 ADC
93.7%
33.6 VDC/33.0 VDC
18.0 VDC (adj)/25.0 VDC
Yes, using two MS4024 units
25 watts
105 ADC
29 AAC
58 lb (26.3 kg)
60 lb (27.2 kg)
Page 49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnasine ms2012Magnasine ms2812Magnasine ms4024

Table of Contents