Appendix A - Specifi Cations And Optional Equipment; Inverter/Charger Specifi Cations - Magnum Energy MagnaSine Hybrid MSH3012RV Owner's Manual

Pure sine wave inverter/charger
Table of Contents

Advertisement

Appendix A – Specifi cations
Appendix A – Specifi cations and Optional Equipment
A-1 Inverter/Charger Specifi cations
Inverter Specifi cations
Input battery voltage operating range
Input battery voltage range for full output power
AC Output Voltage Accuracy (at 12.6 VDC)
Output frequency and accuracy
Total Harmonic Distortion (THD)
Max Continuous power output (at 25°C)
Max Continuous AC output current (Invert mode)
Max Continuous AC output current (Standby mode)
1 msec surge current (amps AC)
100 msec surge current (amps AC)
5 sec surge power (real watts)
30 sec surge power (real watts)
5 min surge power (real watts)
30 min surge power (real watts)
Maximum continuous input current
Inverter effi ciency (peak)
HBCO/HBCI (High Battery Cut Out/In)
LBCO/LBCI (Low Battery Cut Out/In)
Inverter stacking (series or parallel)
AC relay transfer time (minimum)
Power consumption – searching
Power consumption – inverting (no load)
Output waveform
Charger Specifi cations
Continuous charger output at 25°C
Input current for continuous rated output
Maximum current during load support
Charger effi ciency
AC input frequency range
AC input voltage range (remote setting dependent)
Power factor
General Features and Capabilities
Transfer relay capability
Five-stage charging capability
Battery temperature compensation
Internal cooling
Internal protection
RVIA "RV-C" (CAN) compliant
Corrosion protection
Safety listings
Warranty
Environmental Specifi cations
Operating temperature
Non-operating temperature
Operating humidity
Physical Specifi cations
Unit dimensions (length x width x height)
Shipping dimensions (l x w x h)
Mounting
Weight
Max operating altitude
Specifi cations @ 25°C – Subject to change without notice.
Page 49
Model
Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Standard with available temp sensor connected (battery temp 0 – 50 °C)
0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan
Over-current protection and multipoint over-temperature protection
Yes, with electrically isolated CAN port - supports up to 2 inverters per network
PCB's conformal coated, powder coated chassis/top, and stainless steel fasteners
ETL listed to UL/cUL 458, CSA C22.2 No. 107.1-01
13.75" x 12.65" x 8.0" (34.9 cm x 32.1 cm x 20.3 cm)
Shelf or wall (vents can not face downward unless ME-CB or MPX-CB installed)
Unit: 55 lbs (24.9 kg) / Shipping: 63 lbs (28.6 kg)
MSH3012RV
9.0 to 17.0 VDC
10.4 to 17.0 VDC
120 VAC ±3% (≤ continuous power)
60 Hz ± 0.05 Hz
< 5%
3000 VA
25 A (inverting from battery)
60 A (pass-through + load support)
85
45
3500
3500
3400
3100
400 ADC
88.0%
17.1 VDC /16.5 VDC
9.0 VDC (adj) / 12.5 VDC
No
<16 msec
10 watts
36 watts
Pure Sine Wave
125 ADC
18 AAC
224 ADC from battery
86%
50 to 70 Hz
120 VAC nominal (65 to 140 VAC)
> 0.95
50 AAC maximum each input (2 inputs)
3 years parts and labor
-4°F to +140°F (-20°C to +60°C)
-40°F to +158°F (-40°C to +70°C)
0 to 95% RH non-condensing
19" x 17" x 13" (48.3 cm x 43.2 cm x 33 cm)
15,000 ft (4570 m)
© 2020 Sensata Technologies