A-1 Inverter/Charger Specifi cations
Inverter Specifi cations
Input battery voltage range
Absolute maximum DC input
AC output voltage accuracy
Output frequency and accuracy
Total Harmonic Distortion (THD)
Continuous power output (at 25°C)
Continuous AC output current
1 msec surge current (amps AC)
100 msec surge current (amps AC)
5 sec surge power (real watts)
30 sec surge power (real watts)
5 min surge power (real watts)
30 min surge power (real watts)
Maximum continuous input current
Inverter effi ciency (peak)
HBCO/HBCI (High Battery Cut Out/In)
LBCO/LBCI (Low Battery Cut Out/In)
Inverter stacking (series or parallel)
AC relay transfer time (minimum)
Power consumption – searching
Power consumption – inverting (no load)
Output waveform
Charger Specifi cations
Continuous charger output at 25°C
Input current for continuous rated output
Maximum current during load support
Charger effi ciency
AC input frequency range
AC input voltage range
Power factor
General Features and Capabilities
Transfer relay capability
Five-stage charging capability
Battery temperature compensation
Internal cooling
Overcurrent protection
Over-temperature protection
Corrosion protection
Safety listings
Warranty
Branch-rated output circuit breakers
Environmental Specifi cations
Operating temperature
Non-operating temperature
Operating humidity
Physical Specifi cations
Unit dimensions (length x width x height)
Shipping dimensions (l x w x h)
Mounting
Weight
Max operating altitude
Specifi cations @ 25°C - Subject to change without notice.
Page 43
Model
MSH3012M
9.0 to 17.0 VDC
400 ADC
16.8 VDC/16.5 VDC
9.0 VDC (adj)/12.5 VDC
125 ADC
224 ADC
Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Standard with available temp sensor connected (battery temp 0 - 50 °C)
0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan
PCB's conformal coated, powder coated chassis/top, and stainless steel fasteners
Shelf or wall (vents not allowed to face downward unless ME-CB or MPX-CB is installed)
25 VDC
120 VAC ±3% (≤ continuous power)
60 Hz ± 0.05 Hz
< 5%
3000 VA
25 A
70
40
3900
3800
3200
3000
90.0%
No
<16 msec
<7 watts
30 watts
Pure Sine Wave
18 AAC
87%
50 to 70 Hz
60 to 140 VAC (120 VAC nominal)
> 0.95
60 AAC maximum each input
Yes, with two overlapping circuits
Yes, on transformer, MOSFETS, and battery
ETL listed to UL/cUL 458, CSA C22.2 No. 107.1-01
3 years parts and labor
No
-20°C to +60°C (-4°F to 140°F)
-40°C to +70°C (-40°F to 158°F)
0 to 95% RH non-condensing
13.75" x 12.65" x 8.0" (34.9 cm x 32.1 cm x 20.3 cm)
19" x 17" x 13" (48.3 cm x 43.2 cm x 33 cm)
Unit: 55 lb (24.9 kg) / Shipping: 63 lb (28.6 kg)
15,000 ft (4570 m)
MSH4024M
18.0 to 34.0 VDC
35 VDC
4000 VA
33 A
120
72
5800
5400
4900
4500
267 ADC
93.7%
33.6 VDC/33.0 VDC
18.0 VDC (adj)/25.0 VDC
No
25 watts
110 ADC
28 AAC
160 ADC
© 2013 Magnum Energy, Inc.