Appendix 7.15 FCUA-R220 Cable Manufacturing Drawing

Appendix 7.15 FCUA-R220 Cable Manufacturing Drawing
Application:
Supply of 24V to control unit,
remote I/O unit and communication terminal
Assembly drawing
1 2
Note (3)
Connection diagram
3
FG
2
GND
1
+24V
Manufacturing precautions
(1) The wire material shall be a shielded 1-pair stranded cable equivalent to AWG20 (0.5mm
If the cable is 10m or longer, select AWG16 (1.25mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(4) Install each crimp terminal side after stamping the name of each signal on the mark tube.
(5) Protect both ends of the wire material with insulation bushing.
(6) Use AWG18 (0.75mm
4
3
R220
R220
FG
GND
+24V
2
) or equivalent for the shield treatment wire material.
I - 100
Get other manuals https://www.bkmanuals.com
Option (Compatible connector set)
FCUA-CN220
(Note that this corresponds only to the
connector on the control unit side.)
List of parts used
Part
No.
name/model
Connector
1
2-178288-3
Contact
2
1-175218-5
Wire material
3
JPVV-SB
1P × 0.5mm
Crimp terminal
4
V1.25-3
Maximum cable length: 30m
WHITE
BROWN
2
) material or equivalent.
Maker
Q'ty
Tyco
Electronics
1
AMP
Tyco
Electronics
3
AMP
BANDO
Electric
(1)
Industry
2
Note (1)
J. S. T
3
FG
GND
+24V