Appendix; Fcua-R220 Cable Manufacturing Drawing - Mitsubishi Electric MELDAS FCU6-DX561 Maintenance Manual

Table of Contents

Advertisement

Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing
Application:
Assembly drawing
1 2
Connection diagram
Manufacturing precautions
(1) The wire material shall be a shielded 1-pair stranded cable equivalent to AWG20 (0.5mm
(If the cable length exceeds 10m, use AWG16 (1.25mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position designated
in the assembly drawing.
(4) Install each crimp terminal side after stamping the name of each signal on the mark tube.
(5) Protect both ends of the wire material with insulation bushing.
(6) Use AWG18 (0.75mm
Downloaded from
ManualsNet.com
APPENDIX 3 CABLE MANUFACTURING DRAWING
Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing
Supply of 24V to remote I/O unit (FCU6-DX561)
Option (compatible connector set)
FCUA-CN220
(Note that this corresponds only to the connector on the remote I/O unit side.)
3
R220
R220
Note (3)
Remote I/O unit (FCU6-DX561) side
DCIN
FG
3
GND
2
+24V
1
2
) or equivalent for the shield treatment wire material.
search engine
No.
Part name/model
Connector
1
2-178288-3
Contact
2
1-175218-5
Wire material
4
3
JPVV-SB
1P × 0.5mm
Solderless terminal
4
V1.25-3
F G
GND
+24V
WHITE
BROWN
2
).)
I-27
List of parts used
Maker
Tyco
Electronics
AMP
Tyco
Electronics
AMP
BANDO
Electric Wire
2
Note (1)
J.S.T.
Max. cable length: 30m
Power supply side
FG
GND
+24V
2
).
Qty.
1
3
(1)
3

Advertisement

Table of Contents
loading

Table of Contents