Changing Light/Dark Switching At The Product Sensor Or The Alternativ Label Sensor; Gen. 1 - Avery Dennison ALS 204 Installation Manual

Labeller
Hide thumbs Also See for ALS 204:
Table of Contents

Advertisement

3
I
NSTALLATION AND DEINSTALLATION
2.2 C
ONNECTING THE SENSORS
Changing light/dark switching
2.2.3
at the product sensor or the
alternativ label sensor
Basically, sensors can be assigned to three dif-
ferent groups regarding the function of pin 2:
a) Pin 2 has no function
b) Pin 2 = input, e.g. for light/dark switching
c) Pin 2 = output, e.g. for an inverse signal
With sensors or type b), the basic switching type can be
changed by connecting pin 2 to +24 V or to ground [44].
For all other sensor types is the absolute rule: Leave
the relevant jumpers open!
Example:
The alternative label sensor pictured in [43] has an in-
verse output on pin 2. Therefore, JP 901 must be left
open.

Gen. 1

JP 901
Function
JP 902
1)
Pin 2 of the sensor connector is not
connected (default setting)
1)
Pin 2 of the sensor connector is connected to
+24 V
1)
Pin 2 of the sensor connector is connected to
ground
1) With the board in the pictured position
[44] Controlling pin2 at the sensor connector by placing JP901 resp.
JP902
A A
B
[43] CPU board „Gen. 1".
A Position of the jumper JP901 (A) for the control of pin 2 of
the alternative label sensor
B Position of the jumper JP902 (B) for the control of pin 2 of
the product photoelectric sensor
32
ALS
20X
256
A6379

Advertisement