Connecting the external
2.1.6
operator panel
The external operator panel is necessary, if the labeller
is installed at an inaccessible place.
The cable installed to the operator panel is 2.5 m long.
CAUTION!
If the connection cable is longer than 2.5 m,
EMC-caused disturbances can occur.
Only use the factory-installed cable.
Don´t extend the cable.
External and built-in operator panel can be used alter-
nately.
Connect the external operator panel to the mini-DIN
connection [25A].

Mounting the external operator panel

Tool:
– Cross-head screwdriver, medium size
Drill 2 holes according to the drawing beside
[26, Arrows].
Open the operation panel housing (4 screws).
Mount the lower part of the housing using 2 M4
screws.
Close the operator panel housing.
,
ASSEMBLING AND CONNECTING THE MACHINE
[24] External operator panel (Article number: A7474)
[25] Connection (A) for external operator panel.
[26]] Hole distances for wall mounting of the external operator
panel.
23