3
I
NSTALLATION AND DEINSTALLATION
2.1 U
NPACKING

Checking the supply voltage setting

ALS 256: A power supply setting is not re-
quired.
ALS 20X: the labellers are designed for use
with a supply voltage of 230 V (AC) or
110 V (AC).
Check whether the voltage set matches your local
supply voltage.
Permitted mains supply
Switch position
voltage
115
100-120 V (AC)
230
200-240 V (AC)
[21] Permitted mains supply voltages for the two positions of the volt-
age selection switch.
To change the voltage setting:
Ensure that the mains power supply lead is un-
plugged.
Slide the switch [20A] into its other position.
– To do this, insert a small screwdriver into the
[20B]
groove
and push the red insert horizontally
until it stops in the opposite position (for case shown
[20], to the left).
in fig.
,
ASSEMBLING AND CONNECTING THE MACHINE
B
A
[19] Machine with splash guard (A).
[20] Voltage selection switch at the ALS 20X (setting shown in
picture: 230 V)