C a l i b r a t i n g t h e S u p p l y
Calibrate the supply
on initial printer setup
whenever the supply is changed (from black mark to die cut or vice versa)
if using labels with a different color backing (besides white).
Your printer may have a custom application that automatically calibrates supply. The calibration
technique is the same for all supply types. If the printer fails calibration, call Technical Support.
1. Open the printer and lay the supply over the label deflector. It does not matter if a black
mark is over the black mark sensor or not.
2. Close the supply cover.
In the Printer Setup Application, select Supply, then Calibrate Blackmark sensor or
Calibrate On-Demand sensor:
When calibrating the black mark sensor, three labels are used for calibration. The
printer feeds a blank label, looking for the sense mark. The second label is used to
verify the black mark. The third label prints a message if the calibration is successful.
When calibrating the on-demand sensor, the printer feeds a label looking for and
calibrating the die cut. Then, the printer prints a message if the calibration is
successful.