Fitting The Cover Plate; Fig. 69: Fitting The Cover Plate - ABB HT610736 Operation Manual

Table of Contents

Advertisement

Operation Manual / A130-M.. - A145-M..
10 Taking out of operation at short notice / 10.4 Fitting the cover plate
10.4

Fitting the cover plate

Remove turbocharger (see chapter
u
¡
Gas outlet casing removed
Fit the turbine casing with the gas outlet casing into the gas pipe again.
u
Attach the cover plate (see following section).
u
¡
Gas outlet casing not removed
Fit the turbine casing into the gas pipe and on the gas outlet casing again.
u
Attach the cover plate (see following section).
u
Fig. 69: Fitting the cover plate
Make sure that the oil connections in the bracket are equipped with gaskets.
u
1. Close opening in turbine casing (51000) with cover plate (01).
2. Thoroughly clean the fastening strips (51002) before assembly.
3. Coat the threads of the studs (51006) with high-temperature grease.
4. Fasten cover plate (01) to turbine casing (51000) with fastening strips (51002), Verbus
Ripp® washers (51003) and nuts (51007) and screw to bracket.
© Copyright 2022 ABB. All rights reserved.
Removing and Installing
HZTL4031_EN
→30).
Rev.P
February 2022