Alarm
The uplink power has
exceeded the safe limit,
and the receiver has been
turned off
The downlink power has
exceeded the safe limit,
and the receiver has been
turned off
Device is missing
13.1.2

Service Warning

This type of event is one that may be affecting the performance of at least 1 service in at least 1 RU
location, e.g. a bad optical link, Overload "AGC Mode", etc.
2020-03-31 16:55:44: Raised service warning alarm: Downlink Automatic Gain
Control activated on PH Service Module B
Alarm
Configuration has not been
confirmed by the user
The requested composite
power could not be
achieved
Copyright © 2022 Zinwave. All rights reserved.
Description
The power in the uplink (primarily
the Remote Unit) has exceeded the
defined threshold. This will cause
the LNA in the Remote Unit to
switch off until the overload
condition is removed.
It can be caused by uncontrolled
uplink power from mobiles or by
poor installation causing reduction
in Tx Rx isolation.
This relates primarily to the service
Module and is raised when the
downlink power from the connected
BTS or POI exceeds the specified
input level.
A unit that was present at the
application of Validate / Apply
Settings is no longer connected to
the system.
Description
The settings of the system need to
be confirmed by clicking Validate /
Apply Settings.
The output power requested at
System Setup cannot be achieved.
This will be due to a poor optical
link which requires too much
compensation (gain).
Understanding Alarms & Reporting
Action
Remove the overload condition
Check the measured input level and
either modify input settings value or
reduce BTS input level to the level
required.
Correct or accept through System Setup
Action
Run System Setup.
Check Optical connections and link
quality.
13-23