Configuration Of Downstream Primary Hub - ZinWave UNITIVITY 5000 User Manual

In-building wireless solution
Table of Contents

Advertisement

UNItivity 5000
UniTransport System Setup
User Manual
Zinwave recommends that the DL IP power presented to the Downstream PH is set to -25dBm. Also
set the UL AGC Threshold to a little higher than this, -20dBm is recommended.
The settings are calculated when you click Validate Settings, and applied to the hardware when you
then click the Apply Settings button. Expect the calculated uplink gain to be higher than the downlink
gain, even when Uplink/Downlink balance is set to 0dB – this is correct, the overall system gain is
balanced, but the gain split between the upstream and downstream hubs is deliberately not the same
in UL and DL directions.

12.3 Configuration of Downstream Primary Hub

Any Primary Hubs connected to a UniTransport Hub are described as downstream of the UniTransport
Hub. They will have Transport Modules fitted to their Service input slots. These Transport Modules
need to have the same RF input power level assigned to them as the output Transport Modules that
feed them in the UniTransport hub. Zinwave recommends that you set the Calculated Input Level
to -25dBm.
Copyright © 2022 Zinwave. All rights reserved.
12-19