Installing Service Modules In Primary Hub - ZinWave UNITIVITY 5000 User Manual

In-building wireless solution
Table of Contents

Advertisement

UNItivity 5000
User Manual

5.3 Installing Service Modules in Primary Hub

Service Modules are inserted in the back of a Primary Hub in slots A to D. See
descriptions.
Caution: Service Modules must ONLY be installed in the REAR of a Primary Hub.
Optical Modules must ONLY be installed on the front panel of a Primary Hub or the
unit will not function as expected.
To install Service Modules in the back of a Primary Hub:
Note:
If you are adding or updating modules, remove any blanking plates in the rear slots you wish to
populate by turning the retaining screw and pulling on the top and bottom of the plate.
1. Visually align the module with the rear slot (screw hole should be on bottom) and insert with
your thumbs at the top and bottom of the front of the module.
2. Press the module slightly, until you feel it set against the back of the slot.
Modules are equipped with floating BMA connectors in the back that are slightly sprung to enhance
connectivity.
3. Insert a Retaining Screw and hand-tighten.
4. A tightened screw ensures best performance. Performance may degrade if screws are not
properly in place.
5. If power is applied before insertion, see
descriptions.
Note: LEDs will only fully function when equipment on the other end of the fiber is present and working.
Copyright © 2022 Zinwave. All rights reserved.
"Primary Hub Front Panel LEDs"
Installing and Populating Hubs
"Primary Hub"
for LED
for slot
5-6