Remote Unit Led Test - ZinWave UNITIVITY 5000 User Manual

In-building wireless solution
Table of Contents

Advertisement

UNItivity 5000
User Manual
The Service Module LEDs will follow the sequence shown below:
Left
Off
Off
Off
6. Disconnect the optical fiber from the Optical Module connector.
The Optical Module LEDs will alternate between the states shown below:
Left
Off
Off
7. Wait at least 10 seconds then reconnect the optical fiber to the Optical Module. The Optical
Module LEDs will follow the same sequence shown in step 2 above.
It is not possible to initiate a module alarm so the left side LED "RED" state cannot be tested.
Note:
14.2.2

Remote Unit LED Test

In order to test the correct operation of the Remote Unit LED, connect the Remote Unit to an Optical
Module in the front of a Primary Hub. The power supply should not be connected.
The following test sequence should be followed:
1. Power up the Remote Unit by plugging in the power supply The LED will follow the sequence:
a. OFF – RED – ALT. RED/GREEN – GREEN FLASH – GREEN
2. Using "System Setup" disable the Remote Unit output
a. The LED will FLASH GREEN
3. Using "System Setup" re-enable the Remote Unit output
a. The LED will go GREEN.
.
Copyright © 2022 Zinwave. All rights reserved.
Middle
Right
Off
Off
Green
Middle
Right
Red
Off
Performing Diagnostics and Testing
Status
Initial start-up. Basic Power
Dull Red
present to allow Module detection
Module detected and full power
Green
connected to module
Green
Module Fully Operational
Status
Communication failed with Remote
Green
Unit
Basic Power present to allow Module
Dull Red
detection
14-3