Start-Up Sequence; Service Module; Optical Module - ZinWave UNITIVITY 5000 User Manual

In-building wireless solution
Table of Contents

Advertisement

UNItivity 5000
User Manual

3.4 Start-up Sequence

3.4.1 Service Module

The following table shows a typical LED start-up sequence for a fully enabled Service Module:
Left
Off
Off

3.4.2 Optical Module

The following table shows a typical LED start up sequence for a fully enabled Optical Module:
Left
Middle
Off
Off
Off
Off
Green
Flash
Green
Copyright © 2022 Zinwave. All rights reserved.
Middle
Right
Off
Green
Right
Off
Dull
Red
Off
Green
Red
Green
Green
Green
Green
Green
Green
Green
Status
Dull Red
Initial power-up. Power present on Hub
allowing Service Module detection; or
Service Module NOT Enabled through
System Setup; or
Service Module inserted in invalid
slot. (E.g. In an output (front) slot).
Green
Service Module successfully detected
and in normal operation; or
Service Module with Service Warning; or
Service Module with Service Loss.
Status
Initial power-up. Power present on Hub allowing Optical
Module to be detected; or
Optical Module NOT Enabled through System Setup; or
Optical Module inserted in invalid slot. (E.g. In an input
(rear) slot).
Optical Module successfully detected, starting discovery
of downstream system elements.
Potential communication failure state: No incoming light
on fiber or no downstream system elements have
responded after several communication attempts
(discovery continues).
Communication success state: communication with at
least one downstream system element successfully
established.
Optical calibration and auto-setup of downstream units in
progress, and/or one or more downstream Remote Units
have their radio transceivers disabled.
Optical Module and all downstream system elements
operating normally.
Hub and Module LEDs