4. MOUNTING

This chapter describes the mounting of the "made by VIDICODE" version of the APRESA server. If you
use another brand of server then things may be different in your situation.
A full APRESA installation involves the following steps:
• Choosing the location to install the unit;
• Fixing the unit on the selected location;
• Apply power;
• Telecom or network wiring.
4.1.

Location considerations

The environmental requirements for reliable and safe operation of an APRESA server are in general
quite standard for systems based on PC technology:
-
Clean office environment / server room;
-
Protection from direct sun light;
Restricted access;
-
-
Temperature 0-40 °C;
-
No vibration;
-
FLAT surface when used as desk top.
As the best location, we advise to install the APRESA server is your computer server room.
Always install the APRESA server in close proximity of the PBX and phone patch panel as there are
maximum cable length restrictions to deal with.
The APRESA call recorder is capable of recording various telephone systems:
• VoIP telephony;
• POTS telephony;
• TDM telephony ;
• ISDN-2 telephony;
• ISDN-E1 or ISDN-T1 telephony;
• ..... Or a combination of the systems above.
When an APRESA server is required to interface to various different telephone systems (e.g. VoIP and
POTS combined) it may sometimes be difficult to meet all maximum cable length restrictions required by
the various telephone systems. When you have to make trade-offs in cable planning realize that some
systems are more forgiving / tolerant then others:
AUDIO
INSTALLATION MANUAL APRESA
Less critical system in terms of wiring
POTS
ISDN2
COPYRIGHT © 2011-2017 VIDICODE ®
TDM
ISDN-E1/T1 TETRA / VOIP