11.2. General information

The hard drive/RAID condition is continuously monitored by APRESA and the status
shown to the user under
Storage in ALARM
Note: Occurred alarms must be manually cleared by hitting the 'Reset resettable
alarms' button below the System Information panel.
During configuration, the user can select how the APRESA will report alarm
conditions. When configurated properly, an alarm condition can be reported by:
• E-mail
• And/or SNMP
• And/or the alarm card option (Vidicode ART. 010.04663).
11.3. How to replace a failing hard drive in a HARDWARE-RAID volume
On the server, the failing hard drive is easily identified by a RED LED permanently lit
on. Because the hard drives support hot insertion, just replace the defective one for a
new one. The newly inserted drive will automatically be detected by the hardware
RAID-controller and be rebuild into the RAID volume. During process that take 1 or
more hours, of rebuilding the RED LED is flashing, to be turned off when fully rebuild.