Total Power (W): total of all the port power that provided to PD.
Port: select the port that you want to configure from the drag down menu in the bottom of the interface.
Enable: enable or disable the port status.
Power Limit by Classification: Enabling or disabling power classification function.
Power Limit by Management: Enabling or disabling the port power limit management for POE
power management.
Detect Legacy Signature: The legacy detection is to identify the PD devices that did not follow
the IEEE 802.3af standard their unique electrical signatures in order for the PoE switch can
provide the power to those PD devices.
Priority: Set port priority for the POE power management. 1 = C (critical), 2 = H(High), 3 = L(Low).
Power Limit Max (mW) (<15400): Set the power limit value. The maximum value must less
15400.
Fault Status: the PD error status message. There are three error status and explain as following.
Null: It means there is no PD connected or the connected PD device status is normal.
Overload: It means the current is over the PD current classification limited (475mA @
48V DC) that the situation happens over 50msec.
Mode Status: the PD current operation mode status.
V sample or I sample: It means "Current sample or Voltage sample". When PD is
detected and current is supplied, the POE switch will keep detecting and sampling
some current or voltage to ensure whether the PD still present on this port. It is an
IEEE 802.3af operating procedure.
R detect: When the port doesn't connect with any PD, the POE switch will poll each
port and detects the resistor.
Discovery R (ohms): display resistance value.
Port Current (mA): display current value.
Port Voltage (V): display voltage value.
Port Power (W): display watt value.
Class Current (mA): display power class. When you enable the "Bypass classification" function,
the class value will not show in here.
Determined Class: display power class. When you enable the "Bypass classification" function,
the class value will not show in here.