CHAPTER 2
MOUNTING THE INTERACTIVE FLAT PANEL
Refer to local building codes to ensure the wall can support the weight of the
l
interactive flat panel (specified in the following table) and mounting equipment.
Model
SMART kapp iQ Pro 55
SMART kapp iQ Pro 65
SMART kapp iQ Pro 65-V2
SMART kapp iQ Pro 75
Use a standard VESA mounting plate (not included) to mount the interactive flat panel on a
l
wall.
Use M8 screws to fasten the wall bracket.
l
Screw length
Fasten force
NOTE
SMART recommends M8 × 30 mm mounting screws for standard installations where the
total wall mount bracket and washer thickness is less than 7 mm.
Because the receptacles might not be easily accessible after the installers mount the
l
interactive flat panel, consider connecting cables for power, computers and other devices
while the interactive flat panel is still in its packaging (see Chapter 3: Connecting power and
devices on page 15).
Before turning on the interactive flat panel for the first time, clean the camera windows and
l
reflective tape following the instructions in Cleaning the camera windows and reflective tape
on page 41.
12
smarttech.com/kb/171000
20 mm + x mm < M8 < 45 mm + x mm
where x is the combined thickness of the wall bracket and washer
97.36–177.01 in-lb. (11–20 N·m)
CAUTION
Do not over-tighten the screws.
Weight
107 lb. (48.4 kg)
138 lb. (62.4 kg)
134 lb. (60.9 kg)
185 lb. (84 kg)