3.3.2 Filter setting for low-pass noise suppression JP (JP201)

JP201 is for selecting whether or not to insert a low-pass noise suppressing filter (20kHz or less) on F2-type filter
board. Set it to short if it is used, and open if it is unused. The factory default is open.

3.3.3 AC-PLC board connector for A2-type (CN201)

CN201 is a connector that connects A2-type filter board to AC-PLC board.

3.3.4 AC-PLC board connector for F2-type (CN202)

CN202 is a connector that connects F2-type filter board to AC-PLC board.

3.3.5 AC-PLC board connector for G2-type (CN203)

CN203 is a connector that connects G2-type filter board to AC-PLC board.
3.4
PMOD conversion board
This section describes the PMOD conversion board. The PMOD1 connector (connector for Digilent Pmod ™
interface) on the AC-PLC board must be a male connector because it is a peripheral module board.
However, the PMOD1 connector is a female connector to avoid risks such as injury and electrostatic damage due to
protrusions. Therefore, in order to use the AC-PLC board as a peripheral module board of Pmod ™, it is converted from
female to male by the PMOD conversion board.
When connecting the PMOD conversion board to the PMOD1 connector, the orientation of the PMOD conversion
board can be either PMOD2 side or PMOD3 side. Connect so that Pin 1 dot is on the upper left.
Figure 3-5 shows the PMOD conversion board.
R30UZ0165EJ0100 Rev.1.00
July 01, 2021
Figure 3-5 PMOD conversion board