Methods For Evaluating Ac-Plc Communications Using Cpx4 Simplemac Gui - Renesas CPX4 AC-PLC User Manual

Table of Contents

Advertisement

CPX4 AC-PLC Evaluation Kit M02D2 RTK0EE0009D02001BJ
2.3
Method for evaluating AC-PLC communications using CPX4 SimpleMAC GUI
The evaluation environment of AC-PLC communication using CPX4 SimpleMAC GUI is shown in Figure 2-5. For
more information about board set and how to launch CPX4 SimpleMAC GUI, see the manual and the Quick Start Guide
of CPX4 SimpleMAC GUI.
Figure 2-5 Evaluation environment for AC-PLC communication using CPX4 SimpleMAC GUI
Follow the procedure below to set the evaluation environment.
1)
Set the Filter board, SWs and JPs that suit the user's usage environment, such as the band to be evaluated, the
BOOT method, and whether or not the MCU is used.
2)
Connect the USB cable to the USB port of the PC and the USB port (CN5) of the AC-PLC board.
3)
Connect the AC adapter to the power connector (CN4) on the AC-PLC board.
4)
Confirm that LED3 (green) and LED4 (green) of the AC-PLC board are lit.
5)
Connect the AC cable for PLC connection to the PLC connector (CN3) of the AC-PLC board.
6)
Launch CPX4 SimpleMAC GUI on the PC. (Refer to the CPX4 SimpleMAC GUI User's Manual for the
following settings.)
R30UZ0165EJ0100 Rev.1.00
July 01, 2021
3.Interface Specifications
Page 25 of 53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rtk0ee0009d02001bj

Table of Contents