Rev A04
•
CLI-1 is for the left side sMBE and CLI-2 is for the right side sMBE.
•
Eth-1 is for the left side sMBE and Eth-2 is for the right side sMBE.
Table 24 - Control Board LED Indicators
Indication
sFB 1 to 4 (Green)
Temp (Orange)
SM Active – 1 (Green)
CM Active – 1 (Green)
CM Active – 2 (Green)
SM Active – 2 (Green)
Eth 1 and 2
•
Reset Button
•
Press 1-6 seconds for soft reset
•
Press for more than 6 seconds for hard reset
80
Mellanox Technologies
Figure 53: Control Board (sCTRL) Front Panel
Indicates the presence of an sFB in the chassis. Each LED corresponds to one sFB slot:
ON – indicates that an sFB is installed
OFF – indicates that no sFB is installed
Indicates an over-temperature fault on the chassis:
ON – indicates on over-temperature fault
OFF – indicates normal temperature levels
Indicates the Subnet Manager status on a specific sMBE:
Blinking – indicates standby mode.
OFF – indicates that SM off (not in Standby or Active).Subnet Manager is related to the
multi-path master function (topology-related feature).
Chassis manager running on sMBE #1
Chassis manager running on sMBE #2
Indicates the Subnet Manager status on a specific sMBE
•
Blinking – indicates standby mode.
•
OFF – indicates that SM off (not in Standby or Active).
Subnet Manager is related to the multi-path master function (topology-related feature).
Each Ethernet port, used for the management interface, has two LEDs:
•
Link (Green)
•
Activity (Orange)
Final Checks, Operation and Troubleshooting
Description