9. What to do in case of faults 
 
 
 
No.: 
Message: 
8026 
Binding wire in middle 
broken on right  
8027 
Binding wire on right 
broken  
8031 
Error in the "compactor 
forward" function 
8032 
Error in the "compactor 
backwards" function 
8033 
Error in the needle up 
function 
 
 
 
 
Cause: 
This message appears if: the binding wire 
middle right is broken, or the "binding 
wire middle right" proximity switch is 
faulty. 
This message appears if: the binding wire 
on the right is broken, or the "binding 
wire right" proximity switch is faulty. 
This error message appears if: The "ram 
forward" valve is switched on for longer 
than 40 seconds without interruption in 
automated operation . 
Possible cause: 
 
Material jam 
 
 
Channel cylinder not relieving 
 
Pressure sensor defect 
This error message appears if: The "ram 
backward" valve is switched on for longer 
than 40 seconds without interruption in 
automated operation . 
Possible cause:: 
                Pressing plate fastened 
This error message appears if: The "needle 
up" valve is switched on for longer than 8 
seconds without interruption in 
automated operation. The PLC attempts 
to remove the blockages by briefly moving 
back automatically and then forward 
again. If this is not successful even at the 
4th attempt, this message appears. 
Cause:  
Needle channel clogged 
Lower wire jammed 
Proximity switch defect/ 
wrongly set 
Joint thrust needle defect 
04/2015    S. 72 
Remedy: 
Attention special feature 
!!!! 
Replace wire or thread in 
anew. 
Clean proximity switch 
 
Change if necessary 
Attention special feature 
!!!! 
Replace wire or thread in 
anew. 
Clean proximity switch 
 
Change if necessary 
Press "Confirm" button, 
selection switch on 
manual, withdraw press 
shield and remove the 
material jam using 
appropriate mechanical 
aids (rods, pliers, hooks) 
 
 
Valve control defect 
 
Change pressure sensor 
Check cutting gap and 
adjust 
 
 
 
In case of no remedy 
Clean needle channel 
 
 
 
Release lower wire 
 
Clean proximity switch  
Change if necessary 
 
Change  
joint thrust needle  
 
 
Resp. person 
 
 
Operator * 
 
Operator * 
 
Skilled 
personnel 
 
 
Operator * 
 
Operator * 
 
Skilled 
personnel 
Operator * 
 
 
 
 
 
 
 
 
Skilled 
personnel 
 
Skilled 
personnel 
 
Operator * 
 
 
 
Inform customer 
service 
Operator * 
 
 
Operator * 
 
 
Operator * 
Skilled 
personnel  
 
Skilled 
personnel 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CONTI COMPACT CC-20 V and is the answer not in the manual?

This manual is also suitable for:

Conti compact cc-30 vConti compact cc-40 v