Specific Hazards - Presto CONTI COMPACT CC-20 V Operating Manual

Channel baling press
Hide thumbs Also See for CONTI COMPACT CC-20 V:
Table of Contents

Advertisement

 
Safety 
 
 
3.8 
Specific hazards 
 
Danger areas 
 
The danger area of the machine is limited 
in the feeding area to the horizontal 
distance of 1 meter from the external 
dimensions of the channel baling press. 
 
Machine 
 
Electricity:  
 
Five safety rules before commencing 
work: 
 
∗ Switch off 
∗ Secure against being switched on 
(master switch turned off and locked) 
∗ Check that the system is voltage‐less 
∗ Earth 
∗ Cover or fence off any adjacent parts 
which carry live voltage. 
 
Work on the electrical 
system may only be carried 
out by an authorised 
skilled electrician. 
 
 
Before beginning work on electric plants 
and equipment, these have to be 
disconnected from the current supply. 
 
Install this warning sign during the work! 
 
 
 
 
 
Connection to the mains must be carried 
out by the civil engineering contractor in 
compliance with the electrical safety 
instructions, the regulations of the civil 
engineering contractor and the 
information given in the chapter "Electric 
system". 
 
Only use fuses of the prescribed type and 
 
voltage have to be used. 
It is strictly prohibited to repair fuses! 
 
 
 
 
The motor runs in the correct direction 
when the fan wheel of the electric motor 
turns in the direction of the arrow on the 
housing. 
 
Mains supply with rotating field: right  
04/2015    S. 15 
 
CAUTION! 
It is essential to maintain the 
direction of rotation of the 
electric motor. Running in the 
wrong direction even for short 
periods results in destruction 
of the hydraulic pump. 
 
 