2-2-3 How to use the control circuit terminal block (MDS-B-SVJ2-01~07)

(1) For connector of the spring lock type
• Treatment of wire end
(a) Single strand
Peel the wire sheath, and use the wire.
Sheeth
(b) Stranded wire
1) When the wire is inserted directly
Peel the wire sheath, and then twist the core wires. Take care to prevent short circuits with
the neighboring poles due to the fine strands of the core wires. Solder plating onto the core
wire section could cause a contact defect and must be avoided.
2) When the twisted wires are put together using a bar terminal
Use the bar terminal shown below.
Wire size
2
[mm
]
1.25/1.5
2/2.5
Cut the wire running out of bar terminal to less than 0.5 mm
When using a bar terminal for two wires, insert the wires in the direction where the
insulation sleeve does not interfere with next pole, and pressure them.
Chapter 2 Wiring and Connection
Core
Approx. 10mm
Bar terminal type
AWG
For one wire
16
AI1.5-10BK
14
AI2.5-10BU
Less than 0.5mm
Pressure
Pressure
For two wires
AI-TWIN2×1.5-10BK
2-6
Crimping tool
Manufacturer
CRIMPFOX ZA 3
Phoenix contact