Mitsubishi Electric MELDAS MDS-B-SVJ2 Series Specifications And Instruction Manual page 289

Table of Contents

Advertisement

Printing
Specification
date
manual No.
July, 2002
BNP-B3937F
(continued)
Enabled drive of HC102, HC152, HC202, HC203, HC352, HA103N and HA200N
motor with amplifier having one-rank lower capacity than standard, and added
specifications with output limit.
Changed motor type change section from ** to
Preface
Added 3.5kW HC motor to section (4) in Compliance to UL/c-UL
Standards
Added caution indicating software version was C4 and subsequent
versions
Preface 1
Changed from Class 3 to Class C protective grounding (former
Class 3 grounding).
Preface 2
Added caution to turn power OFF if servo amplifier fails
Preface 3
Changed from burns to burns or part damage
Preface 4
Added conductive fine particles to Atmosphere section in table
of environment conditions.
Preface 4 (7)
Eliminated section titled "Disposal" and added explanations
regarding treatment of waste
Preface EC Directives
(1) Configuration
Added configuration drawing
(2) Environment
Changed IEC664 to IEC60664
Changed Pollution Class 2 or more to Pollution Class 2 or less
(6) Peripheral devices
Changed EN60204 ... to Table 5 of EN60204-1 Appendix C
(6) Peripheral devices
Changed Install on wall or open table tray ... to Install on
wall without duct or conduit
Section 1-1-2
Added combinations with HC102, HC152, HC202 one-rank
lower capacity amplifier.
Added HC352, HC203, HA200N and HA103N.
Added detector A47 (OSA17) to HC motor series.
Deleted explanation on HC and HA motor series IP67
specifications
Section 2-4
Changed CNV2 cable to CNV12 cable
Changed MR-JHSCBL cable to CNV2C cable
Section 2-4-1
Added connection of HC52-A47, HC-53-A47 and HC102-A47.
Section 2-4-2
Added connection of HC102-A47, HC-103-A47, HC152-A47 and
HC-153-A47.
Section 2-4-3
Added connection of HC202-A47, HC-203-A47 and HC352-A47.
Section 2-4-4
Added connection of HC103R-A47, HC-153R-A47 and HC203R-
A47.
Section 2-4-9
Added connection of HA103N and HA200N.
Section 2-7
Changed MDS-B-CVE in explanation to MDS-C1-CV.
Section 3-1-1
Added conductive fine particles to Atmosphere section in table
of environment conditions.
Section 3-2-1
Added conductive fine particles to Atmosphere section in table
of environment conditions.
Section 3-2-4
Added HC203, HC352, HA103N and HA200N to table of
characteristics.
Section 3-2-5
Added HC203, HC352, HA103N and HA200N to table of
characteristics.
Section 4-2-1
Added external option regenerative resistor to setting of
regenerative resistor type parameters.
Section 4-2-4
Added characteristics for combination with HC102, HC152 or
HC202 one-rank lower capacity amplifier.
Added HC352, HC203, HA200N and HA103N characteristics.
Revision details
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents