Mitsubishi Electric MELDAS MDS-B-SVJ2 Series Specifications And Instruction Manual page 106

Table of Contents

Advertisement

(9)
HA-FF Series
Motor series name
ABS/INC
Motor capacity symbol
Connected amplifier type (MDS-B-)
No.
Abbrev.
Parameter name
SV001
PC1
Motor side gear ratio
SV002
PC2
Machine side gear ratio
SV003
PGN1 Position loop gain 1
SV004
PGN2 Position loop gain 2
SV005
VGN1 Speed loop gain
SV006
SV007
SV008
VIA
Speed loop lead compensation
Current loop q axis lead
SV009
IQA
compensation
Current loop d axis lead
SV010
IDA
compensation
SV011
IQG
Current loop q axis gain
SV012
IDG
Current loop d axis gain
SV013
ILMT
Current limit value
SV014 ILMTsp Current limit value in special control
SV015
FFC
Acceleration rate feed forward gain
SV016
LMC1 Lost motion compensation 1
SV017
SPEC Servo specification selection
SV018
PIT
Ball screw pitch
SV019
RNG1 Position detector resolution
SV020
RNG2 Speed detector resolution
SV021
OLT
Overload time constant
SV022
OLL
Overload detection level
Excessive error detection width
SV023
OD1
during servo ON
SV024
INP
In-position width
SV025
MTYP Motor/Detector type
Excessive error detection width
SV026
OD2
during servo OFF
SV027
SSF1
Servo function selection 1
SV028
Compensation function for special
~ 035
functions
SV036
PTYP Regenerative resistor type
SV037
Compensation function for special
~ 046
functions
SV047
EC
Inductive voltage compensation gain
SV048 EMGrt Vertical axis drop prevention time
Position loop gain 1 in spindle
SV049
PGN1sp
synchronous control
SV050
Compensation function for special
~ 064
functions
Chapter 4 Setup
This is only for ABS specifications. This can be used with the INC system.
053
SVJ2-01
Set the motor side gear ratio in PC1 and the machine side gear ratio in
PC2.
When using a rotary axis, set the total deceleration (acceleration) ratio.
Refer to 4-2-4 Parameters set according to machine load inertia
Refer to 4-2-4 Parameters set according to machine load inertia
8192
8192
500
500
227C
4-14
HC-FF
13
23
SVJ2-01
SVJ2-03
SVJ2-03
33
0
0
0
4096
4096
4096
4096
300
700
300
700
500
500
0
0
Refer to 4-2-1 Servo specification parameters
Set the ball screw pitch with an mm unit.
Set 360 for a rotary axis.
8
8
60
150
Refer to 4-2-3 Parameters set according to feedrate
50
227D
227E
Refer to 4-2-3 Parameters set according to feedrate
4000
0
Refer to 4-2-1 Servo specification parameters
0
100
0
15
0
33
43
63
SVJ2-04
SVJ2-06
4096
4096
4096
4096
4096
4096
500
700
700
500
700
700
227F
2270
2271

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents