2-9-3 External emergency stop signal (EMGX) input circuit
Issue a signal with a relay or open collector transistor. When using an external power supply, the
power supply for the contactor control output and motor brake control output is the same external
power supply.
MDS-B-SVJ2
MDS-B-SVJ2
Chapter 2 Wiring and Connection
24VDC
CN3
10 VDD
5
COM
4.7k
20 EMGX
3
SG
24VDC
27VDC
CN3
or less
10 VDD
5
COM
4.7k
20 EMGX
3
SG
For a transistor:
≦ 1.0V
V
CES
≦ 100 μ A
I
CEO
Approx. 5mA
toward the power
supply
External emergency stop
canceled by closing.
For a transistor:
≦ 1.0V
V
CES
≦ 100 μ A
I
CEO
A toward
the power
supply
External emergency stop
canceled by closing.
2-34
External emergency stop
External emergency stop