Lubrication
You should only use Kluberplex BEM 34-132 as the standard lubricant for ANT130L stages.
If the application process uses only a small portion of travel for most of the duty cycle, periodically
drive the stage through full travel to redistribute the lubrication in the bearings.
IMPORTANT: During the lubrication procedure, inspect the linear motion guides for
damage or signs of wear.
1. Drive the stage table to one end of travel and remove power to the stage.
2. Remove any accumulated dust or debris that is visible inside of the assembly.
3. Remove any dirty or dried lubricant from the v-channels of the linear bearing rails.
Use a clean, lint-free cloth with a side-to-side motion.
l
Use a swab soaked in Isopropyl Alcohol to remove stubborn debris.
l
4. Apply a thin, continuous film of lubricant to the exposed v-channels of the cross rollers on both
ends of the stage.
Aerotech recommends that you use a good quality, natural bristle artist's brush for the applicator.
l
Do not use any applicator that could scratch or otherwise damage the v-channels.
l
5. Manually move the stage to the opposite end of travel.
This will work the grease into the linear bearing guides.
l
The stage table should move freely with little resistance.
l
6. Repeat steps 2 through 4 for any areas covered by the original table position.
7. Restore power to the stage and drive the stage table back to its original position to redistribute
lubricants.