7.2.2 Radar range setup

You may choose the radar ranges you wish to use, from the RADAR RANGE SETUP menu.
After choosing the ranges desired, change the range with the RANGE key to activate range
settings. Available ranges depends on the radar used.
At least two ranges must be turned on. When less than two ranges are turned on you
cannot escape from the RADAR RANGE SETUP menu.
Note that this function is not available with the GD-1720C.
1. Press the MENU key to show the main menu.
2. Press the RADAR RANGE SETUP soft key to show the RADAR RANGE SETUP menu.
0.125nm
0.25nm
0.5nm
0.75nm
1nm
1.5nm
2nm
3nm
4nm
6nm
8nm
12nm
16nm
24nm
36nm
48nm
64nm
72nm
MAXIMUM RANGE XXnm
* = Max. range depends on network radar used and is set on the network radar at installation.
3. Use the Cursor pad to select the range which you want to turn on or off.
4. Press the ON/OFF soft key to turn a range on or off as appropriate.
5. Press the RETURN soft key to register settings.
6. Press the MENU key to close the menu.
Model
1824C, 1724C, 1734C
1834C
1934C
1944C
1954C, 1964C
RANGE
ON
SETUP
ON
ON
ON/OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
RETURN
ON
OFF
OFF
OFF
*
Range unit: nm
Radar range setup menu
Maximum Range
24 nm, km, sm
36 nm, km, sm
48 nm, km, sm
64 nm, km, sm
72 nm, km, sm
7. CUSTOMIZING YOUR UNIT
0.25km
ON
0.5km
ON
0.75km
ON
1km
OFF
1.5km
ON
2km
OFF
3km
ON
4km
OFF
6km
ON
8km
OFF
ON
12km
16km
OFF
24km
ON
36km
ON
48km
OFF
64km
OFF
72km
OFF
*
MAXIMUM RANGE XXkm
Range unit: km
RANGE
SETUP