Installation
7
Installation
7.1
Safety instructions and requirements
Requirements:
– The product is fully assembled.
– The product is aligned and tested.
– The transportation locks for the moving parts are removed.
– The power supply is switched off.
– The compressed air supply is switched off.
DANGER
Injury or death due to electric shock.
• Before working on the product: switch off the power supply and lock it to prevent reconnection.
When working on the product, observe the following:
– Never connect the plug connectors and electrical interfaces when the power is connected.
– Observe the handling specifications for electro-statically sensitive devices.
– Do not disconnect or connect tubing when the compressed air supply is switched on.
7.2
Cables and tubes
7.2.1
General
Cables
– The cables must be uniquely identifiable.
– Label the cables prior to installation.
– Attach one inscription label each at the beginning and end of the cable near the plug.
Hoses
– The tubing must be uniquely identifiable.
– Only use tubing with material type PUN-H.
7.2.2
Chamber allocation for energy chain
The energy chain is divided into chambers by separators.
The chambers are shown schematically from the point of view of the open end of the energy chain.
The energy chain is not allocated in the delivery status.
Energy chain Y-module
Energy chain chambers
22
Proposal for allocation
1
Customer-specific
2
Hoses
3
Encoder cable
Festo — YXCS — 2021-07b