6.3.7

Sine Cosine Incremental Signals (Option SC50)

Optionally Sine Cosine signals with 1 Vpp are available. (push/pull output, short circuit resistant)
Example "emulation switching"
Parameter
Medium voltage
Amplitude
Relationship
Difference of phase
Distortion factor
Description
min.
Um (sin),
2.4
Um (cos)
sin – sin
400
cos - cos
(sin – sin) /
0.9
(cos – cos)
85
φ
K
-
21
Installation / Commissioning
typ.
max.
2.5
2.6
500
600
1.0
1.1
90
95
+/- 10%
-
3
Unit
V
mV
-
° Degree
%