Connection To A Rs422 Master; Ssi - (Option Sb0 Or Sg0) - ELGO Electronic EMAX2 Series Operation Manual

Magnetic absolute length measuring system with 0.01mm resolution
Table of Contents

Advertisement

6.3.3

Connection to a RS422 Master

Colour
Function
Green
RX
Violet
RX-
Yellow
TX
Orange
TX-
 
Brown
+24VDC
White
0 V (GND)
6.3.4

SSI - (Option SB0 or SG0)

Principle of the function: If the clock is not interrupted for the time Tm-T/2 (output of further 25 periods), the
shift register clocks once again the same data value (error recognition in evaluation).
Some encoders contain a Power Failure Bit (PFB):
With EMAX the PFB is always „low".
Read out of the data (2 times with 25 clocks):
PFB = Power failure bit
T
= Cycle duration of clock pulse
Tm = Mono flop time > 15
μ
s
By using the decoding switch, which is located behind a protection cap on the top of the sensor, the data
format of the SSI interface can be changed over with the help of a micro screwdriver from Binary code to
Gray code.
Not inverted SSI Clock
LED
Gray / Binary code
17
Installation / Commissioning
Position
Code
F
Binary
0
Gray
Switch position:
0
Gray code
1
Binary code

Advertisement