Function At The Operator Level; Actual Value To Reference; Switching Incremental Or Absolute; Activation Offset Measurements - ELGO Electronic IZ15E-010 Series Operation Manual

Horizontal section display battery-powered length measuring system
Table of Contents

Advertisement

10.5 Function at the Operator Level

Working with the device

10.5.1 Actual Value to Reference

With this shortcut, the actual value (display value) on the adjustable reference value is set (in absolute mode only
possible when the offset is not enabled).
The reference value can be entered with the parameter P09.
10.5.2 Switching incremental
With this key the indicator is switched from absolute mode to incremental mode:
The display value is temporarily set to ZERO (sub the saw blade value in P28) and the counting direction is
switched.
The symbol „INC" appears in the display.
Actuating the key again the value is set again to ZERO (sub the saw blade value in P28)
10.5.3 Switching absolute
With this key the indicator is switched from incremental mode to absolute mode.
The counting direction is switched again to the standard and in in the display is shown the symbol "ABS"

10.5.4 Activation Offset Measurements

This key enables/disables each of the three adjustable offset dimensions (only possible in the absolute mode). In
each case an offset is added to the display value.
The activation of an offset level is indicated by the symbol "Offset".
The offset measurements can be entered in the parameter P24.
Keys 1x press at the same time
1x press
1x pressed