Technical Data - ELGO Electronic EMAX2 Series Operation Manual

Magnetic absolute length measuring system with 0.01mm resolution
Table of Contents

Advertisement

4 Technical Data

Mechanical Data
Measuring principle  
Repeat accuracy  
System accuracy in µm at 20 °C           
Distance from the sensor to  
magnetic tape                    
Basic pole pitch 
Sensor housing material  
Housing dimensions 
Necessary magnetic tape 
Max. measuring length 
Cable connection 
Weight 
Ambient Temperature
Storage temperature 
Operation temperature 
Protection class 
Electrical Data
Power supply 
Periodic and random deviation 
Current consumption 
Interfaces 
Resolution 
Max. output frequency  
Sensor cable 
absolute 
+/‐ 1 increment 
+/‐ (150 + 20 x L)  (type design. 010)   
+/‐ (50 + 20 x L)  (type design.  F10)  
L = effective measuring length   
max. 1.5 mm, 2.0 mm with reduced accuracy 
5 mm 
zinc diecasting 
Sensor: L x W x H = 75 x 24 x 26 mm 
Sensor with guide carriage: L x B x H = 100 x 34 x 48 mm 
Meas. length 10 m: AB20‐50‐10‐2‐R‐11 
Meas. length 20 m: AB20‐50‐10‐2‐R‐12 
EMAX : up to 10 m 
EMAL : up to 20 m 
open cable end 
EMAX2: ca. 100 g without cable 
cable: ca. 60 g per meter 
‐25... +85 °C 
‐10... +70 °C 
(‐25... +85 °C) on request 
IP40 (Standard) 
IP65 (Option V) 
10... 30 VDC +/‐ 10 % 
10 ‐ 30 V: < 10%  
max. 150 mA 
SSI‐Interface, CANopen (DS406), CAN BASIC ELGO (CN0), 
RS422, addressable RS422 
0.01 mm 
4 m/s 
1.5 m standard cable length, others on request, 
drag chain compliant 
8
Technical Data

Advertisement

Table of Contents
loading

Table of Contents