4 Technical Data
Mechanical Data
Measuring principle
Repeat accuracy
System accuracy in µm at 20 °C
Distance from the sensor to
magnetic tape
Basic pole pitch
Sensor housing material
Housing dimensions
Necessary magnetic tape
Max. measuring length
Cable connection
Weight
Ambient Temperature
Storage temperature
Operation temperature
Protection class
Electrical Data
Power supply
Periodic and random deviation
Current consumption
Interfaces
Resolution
Max. output frequency
Sensor cable
absolute
+/‐ 1 increment
+/‐ (150 + 20 x L) (type design. 010)
+/‐ (50 + 20 x L) (type design. F10)
L = effective measuring length
max. 1.5 mm, 2.0 mm with reduced accuracy
5 mm
zinc diecasting
Sensor: L x W x H = 75 x 24 x 26 mm
Sensor with guide carriage: L x B x H = 100 x 34 x 48 mm
Meas. length 10 m: AB20‐50‐10‐2‐R‐11
Meas. length 20 m: AB20‐50‐10‐2‐R‐12
EMAX : up to 10 m
EMAL : up to 20 m
open cable end
EMAX2: ca. 100 g without cable
cable: ca. 60 g per meter
‐25... +85 °C
‐10... +70 °C
(‐25... +85 °C) on request
IP40 (Standard)
IP65 (Option V)
10... 30 VDC +/‐ 10 %
10 ‐ 30 V: < 10%
max. 150 mA
SSI‐Interface, CANopen (DS406), CAN BASIC ELGO (CN0),
RS422, addressable RS422
0.01 mm
4 m/s
1.5 m standard cable length, others on request,
drag chain compliant
8