6.3.6

CAN BASIC ELGO - (Option CN0)

Interface / Protocol:
On request the EMAX2 measuring system is equipped with a CAN interface with ELGO CAN standard
protocol.
The following identifiers are given:
80 (16) + EMAX address
10 (16) + position of decoding switch
device (4 byte telegram)
4Byte acknowledgement telegram
Status:
X = 0
without error
X = 1
error magnetic tape
The address can be adjusted in the range
of 0
to F
by a decoding switch,
(16)
(16)
which is located behind a protection cap
on the top of the sensor housing
LED
Terminating
impedance
19
Installation / Commissioning
= Identifier to request the absolute position
= Identifier contains absolute position of the
EMAX2 (resolution 0.01 mm)
The bit rate can be adjusted by a decoding switch,
which is located behind a protection cap on the top
of the sensor housing
Address
Baud rate
Position
Bit rate
0
500 kBit/s
1
250 kBit/s
2
125 kBit/s