ELGO Electronic EMAX2 Series Operation Manual page 20

Magnetic absolute length measuring system with 0.01mm resolution
Table of Contents

Advertisement

A/B – Incremental Output
(Option HXXX or TXXX)
Optionally two 90° phase shifted square wave channels are available (shaft encoder compatible) with HTL-or
TTL-output level (push/pull)
The EMAX resolution (at 4 edge triggering) can have the following amounts:
2.5 μm; 5 μm; 10 μm; 25 μm (for each pulse edge)
Incremental signals
H2N5 Incremental square wave signals HTL with 2.5 μm resolution
H005
Incremental square wave signals HTL with 5 μm resolution
H010
Incremental square wave signals HTL with 10 μm resolution
H025
Incremental square wave signals HTL with 25 μm resolution
T2N5
Incremental square wave signals TTL with 2.5 μm resolution
T005
Incremental square wave signals TTL with 5 μm resolution
T010
Incremental square wave signals TTL with 10 μm resolution
T025
Incremental square wave signals TTL with 25 μm resolution
Installation / Commissioning