Terminating Impedance - ELGO Electronic EMAX2 Series Operation Manual

Magnetic absolute length measuring system with 0.01mm resolution
Table of Contents

Advertisement

6.3.8

Terminating Impedance

As standard the interfaces CANopen, CAN BASIC ELGO (CN0) and RS422 are supplied with a termination
impedance of 120 Ω inside of the interface input. The termination impedance can be deactivated with the
S3 switch. The SSI interface is also supplied with an integrated termination impedance.
When using option V (encapsulated – IP65) the deactivation of the termination impedance has to be
specified by ordering as option A (without termination impedance).
Switch S3
Position of the switch:
Termination impedance: OFF
Position of the switch:
Termination impedance: ON
22
Installation / Commissioning
In order to deactivate the termination
impedance switch S3 use micro-
screwdrivers counter-clockwise.