Cp80 Controller Features - Centurion D3 Installation Manual

Hide thumbs Also See for D3:
Table of Contents

Advertisement

FEATURE
DESCRIPTION
Gate Limit Settings
Auto-close
Auto-close Time
Mode of Operation
Pedestrian Auto-close
Courtesy Light
Collision Sensitivity*
Auto-close Override
Positive Close Mode
Preflashing
Preflash Time
Collision Counter
Crawl distance
The crawl distance is a length of travel which allows the gate to slow down before reaching the end stop. For heavier
gates with less friction, the crawl distance may have to be increased. When increasing the crawl distance, the origin
marker (Figure 19) must be moved and the gate limits reset as in step 6, page 24.
Where operators have been fitted with a CE chip, the crawl distance value is fixed to a count of 2.
* For CE compliance use a collision sensitivity value of 1 or 2 only
DEFAULT
To speed up the counting while selecting main menu items, temporarily connect the PED
terminal to the COM terminal.

CP80 Controller Features

CP80 Controller Features
STATUS
FEATURE
VALUE
NUMBER
-
1
1
2
2
-
3
1
2
4
3
4
-
5
-
6
1
7
2
3
-
8
1
9
2
1
2
10
3
4
-
11
-
12
-
13
CRAWL
STATUS FLASH
DISTANCE
350mm
700mm
1050mm
STATUS or COUNT
COUNT
VALUE
-
-
-
1 Flash = 1 second
-
-
-
-
1 Flash = 1 second
1 Flash = 10 seconds
-
-
-
1 Flash = 1 second
-
-
-
-
-
-
1 Flash = 1 second
1 Flash = 1 count
1 Flash = 350mm
COUNT
1
2
3
Page 44
DESCRIPTION
See detailed instructions on page 25
ON
OFF (Default)
15 seconds (Default)
STANDARD (Default)
CONDOMINIUM
PIRAC
REVERSING
5 seconds (Default)
120 seconds (Default)
HIGH*
MEDIUM (Default)*
LOW
3 second (Default)
ON
OFF (Default)
MODE 1
MODE 2
MODE 3
OFF (Default)
5 seconds (Default)
4 counts (Default)
1 Count = 350mm
DISTANCE BETWEEN
MARKER AND PINION
500mm
750mm
1100mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D5Cp72slidv3

Table of Contents