Automatic Set-up Routine
1
Gate starts at "crawl" speed to
gate.
NB.
If gate closes, remove power and
reverse motor wires (see page 39) and
restart the procedure from step 6.
(
See Setup troubleshooting Guide,
page 34, step 10.2)
2
Gate hits "open" end stop and reverses
direction running at crawl speed.
3
Gate hits "closed" end stop and
reverses direction running at "FULL "
speed until the Origin Marker passes
the Origin Sensor, then at CRAWL
speed to the end. (
troubleshooting Guide, page 34,
step 10.3)
4
Gate hits "open" end stop and
reverses but now runs at "FULL "
speed.
5
As the gate Origin Marker passes
the Origin Sensor the motor speed
reduces to CRAWL. The gate hits
the "closed" end stop and reverses
at FULL SPEED.
6
Gate stops at "pedestrian" (PED)
position. (
Guide, page 32, step 10.6)
Page 26
open
See Setup
See Setup troubleshooting