Fault Finding Guide Continued...
PROBLEM
Low Battery
Voltage Condition
(STATUS light flashes 3 times)
(Continued)
B
False Collision Detection
(STATUS light flashes
4 times to indicate that
number of collisions have
exceeded COLLISION
COUNTER feature value. Wait
60 seconds, or remove &
reapply all power to reset
operation.)
POSSIBLE CAUSES & SOLUTIONS TO PROBLEM
condition of the battery leads,
!
Check the
connectors. Look for and correct all loose connections and
signs of corrosion.
The battery might be discharged.
!
voltage with the charger connected, if the voltage is below
12.5V then the battery is discharged. The number of
opening cycles per hour may be excessive, thus discharg-
ing the battery. Charge the battery, or fit a 10A power pack
with CP80 PSU) if required.
Charger might be faulty.
!
measure the voltage on the battery leads. It must be
between 13.6V and 13.8V, if not replace the charger.
Battery might be old,
!
in doubt test as follows:
#
Check that the
the battery voltage is above 13.5V with the charger
connected. (If the battery is in a good condition it
would probably pass the test without being fully
charged)
Disconnect the charger
#
Remove the DC Motor leads
#
Controller
#
Apply the DC motor leads
while measuring the battery voltage.
make sure that the moving gate will not pose any
danger.
gate does not move, the battery or motor
#
If the
could be faulty
#
If the
battery voltage remains unchanged,
motor is faulty and must be serviced. If the battery
voltage drops to below 11,2V
must be replaced.
(Before replacing the battery, measure the charging voltage
on the battery leads with the battery disconnected. It must be
between 13.6V and 13.8V, if not, replace the charger.)
!
Check for badly running gate, or something
obstructing the gate.
manually move the gate to check for ease of operation.
!
Check for ants, dirt, oil or water in and around the DOSS
sensor.
DC motor wires for loose connections.
!
Check the
contact of the fuses
!
Check
(main controller). The fuse must tightly snap into place.
Page 38
Measure the battery
Disconnect the battery, and
and might have to be replaced. If
battery is charged
, by ensuring that
from the battery
from the DC
directly to the battery,
.
then the battery
Activate the manual override and
with the fuse holder on CP80
terminals and
WARNING:
First
then the
physically