Centurion D3 Installation Manual page 36

Hide thumbs Also See for D3:
Table of Contents

Advertisement

Fault Finding Guide Continued...
PROBLEM
5
Gate moves a short distance
and stops:
6
Gate starts closing then stops &
reopens:
7
Gate overruns its limits:
8
Unreliable auto-close
POSSIBLE CAUSES & SOLUTIONS TO PROBLEM
!
Check for false collisions with procedure
collision detection
could also flash 4 times if the number of detected collisions
exceeded the COLLISION COUNTER feature value).
!
Intermittent IRB trigger only on closing cycle. Check that
the voltage applied to the beams is appropriate.
!
Spurious trigger. Remote with same coding operated in
area, or intermittent short due to possible moisture on the
FRX or TRG inputs. Monitor FRX or TRG LED's.
!
If the problem is still not solved, the CP80 main controller
might be faulty.
! Check collision sensitivity and other causes with proce-
dure B: False collision detection.
!
Check that the origin marker is correctly positioned as
shown on page 23.
!
Check that the ORIGIN sensor wire
plugged
into the CP80 control card, the DOSS sensor
assembly and the magnetic switch assembly (see items 2
and 21 on page 12)
!
Check that the respective
clipped
into the housing.
origin was accidentally moved,
!
Check if the gate
to 10 of the electrical setup. If so reset the limits.
!
If the problem is not solved, the
might be faulty.
Latching Receiver on TRG
!
override feature.
Long pulse on TRG
!
feature.
Faulty IR Beam
!
signal.
Intermittent power loss
!
A: Low battery voltage condition.
procedure
!
If the problem is still not solved, the
might be faulty.
Page 36
, later in this section (STATUS light
harness is securely
ORIGIN sensor is securely
CP80
, would activate the auto-close
would activate the auto-close override
, check for low voltages with
CP80
B: False
steps 4
main controller
main controller

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D5Cp72slidv3

Table of Contents