10.6
Gate does not open to
pedestrian opening.
Gate does not stop at
pedestrian but continues
all the way to the open
end stop.
12
Gate hits closed end
stop, but does not re-
open
14
Gate hits the endstop.
The gate does not move
STATUS light flashes 5
times and L2 turns on.
The gate stopped short
of either the open or
closed position:
The gate does not close
when pressing TEST:
! Origin marker not positioned correctly. (See Figure 19)
!
Continuous trigger on PED input.
!
Origin Marker not positioned correctly.
Is the magnetic sensor switch functioning correctly? Ensure
the gate magnet passes as close as possible to the sensor.
See page 23.
With the CE chip installed the crawl distance is much longer.
Check that the origin marker is correctly positioned as
shown on page 23.
,
!
Check that the set link has been removed.
!
Check if the LCK & IRB LED's are on.
!
Check if the FRX LED is off.
!
The gate limits were not set correctly. Restart from step 6
on page 24.
!
The gate dynamics could be detected as a collision by the
controller. Set the gate collision sensitivity to be less
sensitive (feature 7 to setting 2 or 3) (See page 44)
!
Mode of operation could be set to condominium, which
only allows the gate to be closed by the auto-close timer.
!
The safety beams or holiday lockout features could be
activated. Check the IRB and LCK lights, both must be ON
for normal operation.
!
The link between COMMON and LCK might not be fitted,
when the safety lockout feature is not used.
!
The link between COMMON and IRB might not be fitted,
when safety beams are not used.