16 Advanced settings

16
Advanced settings
16.1

Learn with advanced setting of "back- and latch-check"

See the prerequisites for performing a "learn" in section
latch check (recommended) on page 71.
a Push the button once as for auto-setting.
The status LED starts to blink. Same as for auto-setting.
b Stop the door at required open position.
c The door reverts towards closed position.
d Stop the door at required latch-check position.
e The door reverts to learn the back check.
f
Stop the door at required back check.
g Remove the stop.
h The door reverts to closed position.
16.2

Revert to default values for "back- and latch-check" (Level 1)

a Disconnect batteries if any.
b Disconnect the mains.
c Press the LEARN BUTTON (LRN) and keep it depressed.
d Connect the mains.
e Watch the ERROR LED.
3 s
f
Release the LEARN BUTTON after 1 flash (LED is out).
g The BACK CHECK, LATCH CHECK and OPEN POSITION have now reverted to default values.
h Disconnect the mains.
i
Next time the mains is connected, a new learn is needed to be run, and the operator will use
the default values.