GENERAL SAFETY PRECAUTIONS This installation manual is intended for professionally competent personnel only. Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with applicable regulations. Before installing the product, carefully read the instructions. Bad installation could be hazardous.
DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY (Directive 2006/42/EC, Annex II-B) The manufacturer DITEC S.p.A. with headquarters in Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY declares that the automation system for CUBIC swing gates: has been constructed to be installed on a manual door to construct a machine pursuant to the Directive 2006/42/EC.
TECHNICAL DATA CUBIC6 CUBI6H CUBIC6HV Power supply 230 V~ 50 Hz 24 V 24 V Absorption 1,5 A 12 A 12 A Couple 340 Nm 340 Nm 220 Nm Capacitor 10 µF Opening time 18 s/90° 12÷25 s/90° 6÷13 s/90°...
The connection to the mains must be made via an independent channel, separated from the connections to command and safety devices. nOTE: the given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
INSTALLATION Unless otherwise specified, all measurements are expressed in millimetres (mm). 6.1 Preliminary checks Check that the structure is sufficiently sturdy and that the hinge pivots are properly lubricated. Provide an opening and closing stop. note: if the gate wing is more than 2.5 m wide, an electric lock should be installed. 6.2 Foundation case installation Install the foundation case as indicated in the relevant manual.
6.6 Installation with CUBIC6L-CUBIC6LG Insert lever [A] on the gearmotor and position the mechanical stop [B] and [C] and adjust it, as shown in the figure. NOTE: the figure shows the motor installed on the right door wing. 6.7 Installation with CUBIC6TC Insert pinion [A] and join the two pinions by means of the chain [B], as shown in the figure.
6.8 Installation with CUBIC6TIG Fix the plate [A], then insert, fix and lubricate the gears [B], [C] and [D]. Position the sphere [E] as shown in the figure. 6.9 CUBIC6FM-CUBIC6FMTI installation It is possible to limit the travel of the wing by means of magnetic limit switches. Choose and install the magnetic limit switches as indicated in the relative manual.
WARNING: the electrical connections for the extension of the motor cables must be made on the outside of the foundation casing in an appropriate junction box (not supplied). In the CUBIC6 gearmotors, the blue wire corresponds to the common contact of the motor phases, and must be connected to the W or Z terminals of the control panel.
CUBIC6 9. Operating instructions 9.1 General safety precautions The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance.
WARnInG: the door wing block and release operations must be performed with the motor idle. Installer: DITEC S.p.A. Via Mons. Banfi, 3 21042 Caronno Pertusella (VA) - ITALY Tel. +39 02 963911 - Fax +39 02 9650314 www.ditec.it - ditec@ditecva.com IP1812EN • 2012-07-10...