12 Electrical connection
12.1.5

Extension unit DAB905ESA

This extension unit has inputs for door mounted sensors, which can give presence impulse on approach side
and/or presence detection on swing path side. Relay output for error indication or door indication is also integ-
rated. When the jumper for the relay is set to 'Open door indication', its activation will follow the Blanking LED.
Functions
Monitoring of presence detection/DMPS.SS
Monitoring of presence impulse/DMPS.NS
Blanking LED
Door position
2)
Door mounted sensors
DMPS:
Relay 1: Presence im-
pulse (NC)
Relay 2: Presence de-
tection (NC)
MIN
MAX
Closed door
Open door
indication
indication
MIN
QTST = Sensor monitoring and reference for KILL (NC)
PDET = Presence detection (NC)
PIMP = Presence impulse (NC)
1)
If not used strap to "Ground".
2)
Remove strapping from terminals 2 and/or 3.
62
No monitoring (both jumpers on)
Monitoring of presence detection and presence impulse
Relay output ( "External error, KILL OUT, Lock indication
NO
"Open/closed door indication", see above) 24 V, 1 A
COM
NC
Note! To make the dry relay output follow the electric lock output,
see group parameters 14, 15 and 16 plus pin jumper above.
FIRE
GND
(+) 24 VDC
24 V DC
QTST
PDET
PIMP
(-) 0 VDC Ground
GND
Ground
Remove strapping when connecting to terminals 2
and/or 3
Blanking potentiometer
(Adjust the potentiometer to avoid presence detection sensor to detect the wall.
Range 55 degrees - fully open / Max.)
Opened / closed door indication
MAX
1)
1)
Issue 2021-06-07
External error indication/KILL OUT/Lock
Opened/closed door indication
Blanking
Blanking
55°
" or
MAX
1020527-DIen-3.0