1. General safety precautions Failure to respect the information given in this manual may cause personal injury or damage to the device. Keep these instructions for future reference This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed by qualified person- nel, in accordance with Good Working Methods and in compliance with the current regulations.
The manufacturer ASSA ABLOY ES AB, with headquarters in Lodjursgatan 10, SE-261 44 Land- skrona, Sweden, declares that the automation for folding doors type Ditec DOR: - is designed to be installed on a manual gate to form a machine pursuant to Directive 2006/42/ EC.
3. Technical data DOR1BH DOR1BHS Power supply 24 V 24 V Absorption 12 A 12 A Torque 300 Nm 300 Nm Max. door weight 500 kg 500 kg Max. door width 1,5 m + 1,5 m 1,5 m + 1,5 m Revolution 2,5 RPM 2,5 RPM...
The connection to the mains must be made via an independent channel, separated from the connections to command and safety devices. NOTE: the given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
5. Installation Unless otherwise specified, all measurements are expressed in millimetres (mm). 5.1 Preliminary checks Check that the structure is sufficiently rugged and that the hinge pivots are properly lubricated. Provide an opening and closing stop. Select installation mode. Geared motor concealed left or right ~120 ~120 ~1/4 L...
5.2 Geared motor installation - To reverse installation of the Dor from left to right, proceed as shown in figure. - Secure the mounting plate to the wing as shown in figure. 62 20 13.5 Ø21 Ø8.5 - Install the geared motor on to the mounting plate.
Page 10
- With the door open determine the mounting position of the arm on the wing, see figure on page 8. - Shorten the tube and if necessary the rod depending on the previously determined mounting positions (geared motor shaft [E] and wing [C]). WARNING: after the tube has been fit in all the way, ensure that it does not knock against the rod’s bush or that the rod’s head does not knock against the screw that secures it to the wing (min.
5.3 Limit switch installation and adjustment (optional) - Connect the limit switch wire fastons to the microswitches. Arrange the limit switch wires neatly inside the microswitch box [1] and route the wire out through the appropriate opening. - Fit the two cams [3] on to the cam ring without tightening the screws. - Install the cam ring on the driving shaft and screw down screw [4] without tightening.
Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout. The electrical connections and starting of the DOR gearmotor are illustrated in the VIVAH control panel installation manual. 7. Routine maintenance plan Perform the following operations and checks every 6 months according to intensity of use of the automation.
Operating instructions General safety precautions for the user These precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and for- warded to all possible future users of the system.
Page 14
must not be carried out by children unless they are supervised. To ensure that the system works efficiently and correctly, the manufac- turer’s indications must be complied with and only qualified personnel must perform routine maintenance on the motorised door or gate. In particular, regular checks are recommended in order to verify that the safety devices are operating correctly.
Manual release instructions In case of faulty operation or power failure, pull the release cord downwards and secure it by means of the appropriate ring (when the DEB04 handle is present work on it). To return to normal operation, release the ring and leave the cord free. The release pin will automatically return to the lock position.